Main Characteristics:
EC type-examination certificate in conformity with
• 2014/32/EU (MID) MI-001 Water Meter
• OIML R49-1 :2006
• EN 14154:2005+A2
• ISO 4064:2015
• EC Type Examination Certificate (RO - 2275- 15286)
• The Quality Assurance of Production Process (Module D)
• Sanitary Compliance or Health Certificate (WRAS)
• ISO 9001:2015
• ISO 14001:2015
• ISO 45001:2018
• ISO 27001:2013
Dimension | Nominal Diameter | DN | mm | 15 |
Size | Inch | 1/2'' | ||
Overall Lenght Without Connectors | L | mm | 165(') | |
Overall Lenght With Connectors | L1 | mm | 230 | |
Thread Meter GxB | D | Inch | 3/4'' | |
Thread Connector | d | Inch | 1/2'' | |
Total Height | H | mm | 106 | |
Total Height (With Lid) | H1 | mm | 170 | |
Width Approx | W | mm | 84,5 | |
Weight | Weight Approx | * | kg | 1,04 |
Package Without Connectors | * | kg | 1,08 | |
Package With Connectors | * | kg | 1,23 | |
Box Dimension (1 Unite) | * | cm | 19x10x9 | |
Package Dimension (10 Unite) | * | cm | 49x23x20 | |
Quantity Per Package | * | unite | 10 | |
(')Also available in length 190 mm | ||||
Threading : EN ISO 228-1 : 2003 |
Performance Data | Metrological Data | Nominal Daimeter | DN | mm | 15 | |||
Size | Inch | 1/2'' | ||||||
Maximum Flow Rate (m3/h) | Q4 | ≤3,13 | ||||||
Nominal Flow Rate (m3/h) | Q3 | ≤2,50 | ||||||
Transitional Flow Rate (l/h) ±2% | Q2 | ≤0,040 | ||||||
Minimum Flow Rate (l/h) ±5% | Q1 | ≥0,025 | ||||||
Measuring Range - Horizantal (R) | Q3 / Q1 | R100 (Class B) | ||||||
Measuring Transitional Flow Rate | Q2 / Q1 | 1,6 | ||||||
Measuring Maximum Flow Rate | Q4 /Q3 | 1,25 | ||||||
Accuracy Class | 2 | |||||||
Technical Data | Maximum Permissible Error For The Lower Flow Rate Zone | (MPE1) | ±5% | |||||
Maximum Permissible Error For The Upper Flow Rate Zone | (MPEU) | ±2 % for water having a temp. ≤30°C ±3 % for water having a temp. >30°C | ||||||
Temperature Class | T °C | T30 and T50 | ||||||
Water Pressure Classes | MAP (Bar) | 16 | ||||||
Pressure - Loss Classes | ∆ P (Bar) | 0,63 | ||||||
Max. Indicating Range | m3 | 99 999 | ||||||
Resolution Of Indicating Device | [litre] | 0,05 | ||||||
Instalation Positions | Horizontal | |||||||
Flow Profile Sensitivity Classes | U0 , D0 | |||||||
Impulse Value | litre/pulse | 1, 10, 100, 1000 | ||||||
Module Type (Optional) | Pulse, MBus (Wired, Wireless), RF, AMR |
MATERIAL | ||||||
1 | BODY (BRASS) | |||||
2 | LID | |||||
3 | GLASS | |||||
4 | REGISTER CAP (BRASS) | |||||
5 | GASKET | |||||
6 | REGISTER | |||||
7 | CENTRAL GEAR | |||||
8 | ANTIMAGNETIC METAL RING | |||||
9 | CLAMPING METARIAL | |||||
10 | TURBINE / VANE WHEEL | |||||
11 | MEASURING CHAMBER | |||||
12 | ADJUSTING PLUG | |||||
13 | ADJUSTING SCREW | |||||
14 | STRAINER | |||||
15 | CHECK (NON-RETURN) VALVE |